Medical X-ray Collimator Automatic X-ray Collimator SR301

Features Suitable for tube voltage 150kV, DR digital and common X-ray diagnostic equipment  The X-ray irradiation field is rectangular Conform to relevant national and industry standards High reliability and high cost performance  Double layers and two sets of lead leaves and a special internal protective structure are used to shield X-rays. The top lead leaves can enter the window of the X-ray tube, which can shield the stray scattered rays more effectively. The adjustment of the irradiation field is manual, continuously adjustable The visible light field adopts high-brightness LED bulbs The internal delay circuit can automatically turn off the light bulb after 30 seconds of light, and can manually turn off the light bulb during the light period to prolong the life of the light bulb and save energy Convenient and reliable mechanical connection with X-ray tube, easy to adjust

Products Details

Applications

This collimator is suitable for tube voltage 150kV, DR digital and common X-ray diagnostic equipmentX-ray leakage: <1mGy/h (150kV, 4mA) The distance from the focus of the X-ray tube to the beam limiter mounting surface: 60mm (can be adjusted according to different tubes) Maximum irradiation field: 48cmX48cm (SID=1m) Minimum irradiation field: <5cmX5cm (SID=1m)  Visible light field brightness: >140lux (SID=1m) Light field consistency: <2%@SID Inherent filtration: 1mmAl/75kV Power input: 24VAC/50W or 24VDC/2A  Dimensions: 200mm×230mm×170mm (length×width×height) Weight: 8.4kg Optional: External additional filter Special electrical interface Special tube ball interface One word line laser locator (Class 1)

Main technical parameters and indicators

Technical parameters

Max Voltage

150KV

Maximum X-ray field  coverage  range

480mm×480mm (SID=100cm)

The average brightness of the light field

>160 lux

Edge contrast ratio

>4:1

Power supply requirement of projection lamp

24V AC/150W

Bright  X-ray  field  duration  for  Once

30S

Distance from Focal Spot of X-ray tube to the mount plane of collimator  SID  (mm)(optional)

60

Filtration(Inherent) 75kV

1mmAl

Filtration(Additional)

The outer optional

Control  method

Manual

Drive motor

--

Motor Control

--

Position detection

--

Input power

AC24V

(SID)Measuring tape

Standard Configuration

Center laser instructions

optional

Dimension(mm)(W×L×H)

200×230×170

Weight(Kg)

8.4