Type: Station anode x-ray tube

Application: For Bone Mineral Densitometer x-ray system unit.

Model: KL32-0.5-80

Equivalent to BRAND X-RAY BX-1

Integrated high quality glass tube


Description: 

KL32-0.5-80 Stationary X-Ray Tube is especially designated for bone densimeter x-ray system and available for nominal tube voltage constant potential circuit

KL32-0.5-80 tube has one focus.

The integrated high quality tube with glass design has one super imposed focal spot and areinforced anode. The high anode heat storage capacity ensures a wide range of applications for bone densimeter x-ray application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

91.jpg


Applications: 

KL32-0.5-80 Stationary X-Ray Tube is especially designated for bone densimeter x-ray system and available for nominal tube voltage constant potential circuit


Specifications:

Nominal Tube Voltage(self-rectified).................................................................................................................................95kV

(constant potential)................................................................................................................................................................80kV

Nominal Tube Current...........................................................................................................................................................2mA

Nominal Operating Condition...........................................................................................................................80kV, 2mA-2.4V

Nominal Anode Cooling Rate............................................................................................................................................160W

Anode Heat storage Capacity .............................................................................................................................................16kJ

Filament current...............................................................................................................................................1.95 A-2.4V±0.2V

Focal spot..................................................................................................................................................0.5 (IEC60336/2005)

Target Angle...............................................................................................................................................................................12°

Effective X-ray Cone Beam.............................................................................................................................................24°X90°

Target Material...............................................................................................................................................................Tungsten

Cathode type..................................................................................................................................................Tungsten filament

Dimensions ......................................................................................................................125mm length by 35mm diameter

Weight..............................................................................................................................................................approx.145 grams

86.jpg


Competitive Advantage: 

Elevated anode heat storage capacity and cooling

Constant high dose yield

Excellent lifetime