Grid-control Dental X-ray Tubes for Intro-oral Equipment KL2

Chat Now
Product Details

Grid-control Dental X-ray Tubes for Intro-oral Equipment KL2


Quick Detail:

Type: Station anode x-ray tube

Application: For intra-oral dental x-ray unit

Model: KL2-0.8-70G

Equivalent to CEI OCX/65-G

Integrated high quality glass tube


Detailed Images

a.jpg


Description: 

KL2-0.8-70G Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit. And it is a grid-control tube.

The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode. It is extremely important to observe the connection diagram and the grid-resistor value. Any change could modify the dimensions of the focal spot, also varying diagnostic performances or overloading anode target.

The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

3.jpg


Applications: 

KL2-0.8-70G Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.


Specifications: 

Nominal Tube Voltage......................................................................................................................................70Kv

Nominal Inverse Voltage..................................................................................................................................85kV

Nominal Tube Current.......................................................................................................................................8mA

Maximum Exposure Times...............................................................................................................................3.2s

Maximun anode cooling Rate........................................................................................................................210W

Max. Anode Heat Content................................................................................................................................7.5kJ

Filament Characteristics...........................................................................................Uf=4.0V(Fixed),If=2.8±0.3A

Focal spot ..............................................................................................................................0.8(IEC 60336 2005)

                                                                   At 70kV 8mA with 5kΩ to 25 kΩbias resister(Fixed)

Grid Resistance Value................................................................recommended by manufacturer for any tube

Target Angle...........................................................................................................................................................19°

Target Material...........................................................................................................................................Tungsten

Cathode type............................................................................................................................................W filament

Permanent Filtration................................................................................Min. 0.5mmAl/50 kV(IEC60522/1999)

Dimensions.....................................................................................................80mm length by 30mm diameter

Weight.......................................................................................................................................................125 grams


Competitive Advantage: 

Elevated anode heat storage capacity and cooling

Constant high dose yield

Excellent life time



Feedback